¡½
Base Specification:
a) IEC 33 (C0) 77¡KUsed for AC motor application
b) JIS C 4908 ¡K.Used for electrical apparatus
¡½ Climate Category: In accordance with
DIN40040 HSF
a)H=Minimum Limit Temperature¡K-25¢J
b)S=Maximum Limit Temperature¡K+70¢J
c)F=Humidity Category¡KAverage relative humidity
¡Ø75%, 95% for 30 days per year, continuously;
85% for the remaining days occasionally.
¡½ Rated Voltage:¡K..250, 350, 400, 450 V.AC,
50~60 Hz
¡½ Capacitance Range:¡K¡K¡K¡K¡K¡K¡K¡K0.1~15.0uF
¡½ Capacitance Tolerance:. J (¡Ó5%), U (+10,
-5%), K (¡Ó10%)
¡½ Withstand Voltage:
a)Between Terminals¡K1.5 x rated voltage
for 10s.
b)Between Terminals and Case
¡K2 x rated voltage + 1000 V (1500 V Min.)
for 60 s.
This test occasional self-healing breakdown
are allowed.
¡½ Dissipation Factor:
¡Ø0.1% at 200 V.AC, 60 Hz and 20¢J (HMP type)
¡Ø0.3% at 200 V.AC, 60 Hz and 20¢J (HME type)
¡½ Insulation Resistance:
a)Between Terminals..¡Ù10 x 103 M£[ for C¡Ø1.0uF;
¡Ù10 x 103 M£[.uF forC¡Ø1.0uF
b)Between Terminals and Case...¡Ù10 x 103
M£[
|