■ Base Specification: a) IEC 33 (C0) 77…Used for AC motor application b) JIS C 4908 ….Used for electrical apparatus
■ Climate Category: In accordance with DIN40040 HSF a)H=Minimum Limit Temperature…-25℃ b)S=Maximum Limit Temperature…+70℃ c)F=Humidity Category…Average relative humidity ≦75%, 95% for 30 days per year, continuously; 85% for the remaining days occasionally.
■ Rated Voltage:…..250, 350, 400, 450 V.AC, 50~60 Hz ■ Capacitance Range:……………………0.1~15.0uF ■ Capacitance Tolerance:. J (±5%), U (+10, -5%), K (±10%)
■ Withstand Voltage: a)Between Terminals…1.5 x rated voltage for 10s. b)Between Terminals and Case …2 x rated voltage + 1000 V (1500 V Min.) for 60 s. This test occasional self-healing breakdown are allowed.
■ Dissipation Factor: ≦0.1% at 200 V.AC, 60 Hz and 20℃ (HMP type) ≦0.3% at 200 V.AC, 60 Hz and 20℃ (HME type)
■ Insulation Resistance: a)Between Terminals..≧1 x104 MΩ for C≦1.0uF; ≧1 x104 MΩ.uF forC≦1.0uF
b)Between Terminals and Case...≧1 x104 MΩ
|