˙Base specification:
|
IEC 33(CO)77 A.C.motor capacitors. JIS C4908 capacitors for electrical apparatus.
|
˙Climatic Category:
|
In accordance with DIN40040 GPF. G=Minimum limit temperature:-40℃ P=Maximum limit temperature:+85℃ F=Humidity category:average relative humidity ≦75%,95% for 30days per year; continuously,85% for the remaining days; occasionally.
|
˙Rated Voltage:
|
250~450V.AC 50/60Hz
|
˙Capacitance Range:
|
0.1~1.0uF
|
˙Capacitance Tolerance:
|
K(±10%)
|
˙Withstand Voltage:
|
(a).Between terminals:1.5 x rated voltage for 10s. (b).Between terminals and case:2 x rated voltage +1000V (minimum 1500V) for 60s. This test occasional self-healing breakdown are allowed.
|
˙Insulation Resistance:
|
(a).Between terminals: ≧30x103MΩ for C≦0.33uF. ≧10x103MΩ /uF for C > 0.33uF. Measured at 100V.DC 60s.and 20℃. (b).Between terminals and case:≧10x103MΩ. Measured at 100V.DC 60s.and 20℃.
|
˙Dry Heat Resistance:
|
In accordance with IEC 68-2-2 test Ba. Conditions Test temperature:Maximum limit temperature. Test duration:16hrs. Test criteria (a).Appearance:No visible damage and no leakage. (b).Capacitance change:≦+2,-5% of the initial value. (c).Insulation resistance:≧10% of initial specified value.
|
˙Cold Resistance:
|
In accordance with IEC 68-2-1 test Aa. Conditions Test temperature:Maximum limit temperature. Test duration:2hrs. Test criteria (a).Appearance:No visible damage. (b).Capacitance change:≦+3,-1% of the initial value.
|
˙Humidity Resistance:
|
In accordance with IEC 68-2-3 test Ca. Conditions Test temperature:+40℃ Relative humidity:90 to 95% Test duration:21day. Test voltage:(a).Without voltage. (b).With rated voltage. Test criteria (a).Capacitance change:≦±4% of the initial value. (b).Dissipation factor:≦0.5 x 10-3(0.05%) of increased value. (c).Insulation resistance:≧50% of initial specified value.
|
˙Endurance:
|
Place the capacitor in the thermostatic oven in accordance with the condition of following: Test A:Continuous endurance test. Test temperature:Maximum limit temperature. Test voltage:1.25 x rated voltage. Test duration:1000±12hrs. Test B:Intermittent endurance test. Test temperature:Maximum limit temperature. Test voltage:1.4 x rated voltage.2s. ON 2s. OFF (15time / min.) Test cycle(time):10 x 104 Test criteria (a).Appearance:No visible damage and no leakage 3 (b).Capacitance change:≦±5% of the initial value. (c).Dissipation factor:≦0.5 x 10-3(0.05%) of increased value. (d).Insulation resistance:≧50% of initial specified value.
|