Dielectric
|
Polypropylene film
|
Electrodes
|
Vacuum evaporated metal
|
Coating
|
Out wrapped with mylar tape and ends seals with epoxy resin
|
Leads
|
Axial leads of tinned wire
|
Reference Standard
|
IEC 384 – 2 grade I ; GB 7334
|
Climatic Catalogue
|
- 40℃ ~ + 100℃
|
Capacitance versus Rated Voltage(UR)
|
100VDC 0.01uF—10uF ; 250VDC 0.01uF—10uF
|
|
400VDC 0.01uF—2.2uF ; 630VDC 0.01uF—1.0uF
|
Capacitance Tolerance
|
M = ± 20% K = ±10% J = ± 5%
|
Dissipation Factor (Tangent of Loss)
|
DF≦0.10% (at 20℃,1KHZ)
|
Voltage Proof
|
1.6×UR (1 minute at 20℃)
|
Insulation Resistance
|
C≦0.33uF IR≧15,000MΩ C>0.33uF IR×C≧5,000MΩ (1 minute at 20℃and RH≦65%)
|
Insulation Resistance
|
C≦0.33uF IR≧15,000MΩ C>0.33uF IR×C≧5,000MΩ (1 minute at 20℃and RH≦65%)
|
Endurance
|
1000 hours with 125% of rated voltage at 85℃, After the test: C/C≦5%; (DF) ≦0.04% C≦0.33uF, IR≧7,500MΩ; C>0.33uF, IR×C≧2,500ΩF (20℃1KHZ)
|